UNIRAC SOLARMOUNT


UniRac’s SolarMount is a fast, easy, safe way to install a
PV  array in virtually any roof or ground installation. Bottom mounting clips and tilt legs supplement traditional top mounting clamps. As a result, the system accommodates the widest variety of installations and assembly preferences – on the roof and on the ground.  Any framed module sold in North America can be mounted using SolarMount.

Lower-cost SolarMount Light Rail employs 38 percent less aluminum than SolarMount Standard Rail, yet it’s more than strong enough for flush applications. Use the same top mounting clamps and footing components that make SolarMount Standard Rail so easy to install.

Once you’ve selected the PV modules and planned your installation layout, you’re ready to choose SolarMount components. The chart on the following page shows what components to use if you are bottom-mounting the modules. The chart on page 30 shows what parts to use if you are top-mounting the modules. If you need tilt legs for the mounts, see the explanation on pages 36-37. Rail and parts to complete your mounting system can be found on pages 31 to 34.

When sizing is complete, rails, splices, and L-feet may be ordered in two ways: In kits or in bulk. 2- and 4-rail kits on page 31 contain just the right quantities of each component for a given installation.

The 8-piece bulk rail bundles on page 32 require 4 bottom-mounting clips (page 33) for every module to be mounted, and the addition of L-feet and splices when necessary.
 

UniRac SolarMount rails can
be mounted vertically or horizontally
 

 

 

 

 

 


Choose a Top-Mounting or Bottom-Mounting System

On pitched roofs, mount rails either parallel or perpendicular to the rafters Assembly sequence is a common determining
factor. Select top-mounting clamps if you prefer to install modules last – after you’ve attached rails to installed footings.
This sequence is especially convenient with modules that have Multi-Connect cables. Select bottom mounting clips if you
plan to attach modules to rails prior to final installation. This sequence is well suited for modules that must be pre-wired.
Bottom-mounting clips use space more efficiently because they do not require the 1" space between modules needed by
top clamps.
The use of top-mounting clamps is generally easier when flush-mounting to a roof. Always use top-mounting clamps
when flush mounting to standoffs. If using bottom-mounting clamps with L-feet, follow the installation manual carefully
to make sure footing slots are accessible during final installation.
In roof mounts, when using top-mounting clamps, no extra roof bracing is needed since rails or mounting feet can be
adjusted to match rafter spacing. With bottom-mounting clamps, spacing between the rails depends on spacing between
the mounting holes of your particular PV module, and it is unlikely that they will match rafter spacing. In that case, place
a stringer over the roof or mounting blocks beneath it. Never attach footings to the sheathing alone – such an arrangement
will not meet code and will leave the installation and roof vulnerable to severe damage from wind.
 


 

UniRac Bottom Mounting Sizing Rail set lengths

This chart lists the length of the rails required for many common modules.
If you need rail sizing for a module not listed below, please contact us.

 

 

 

 

Module Brand and Model

Rail length (inches) by number of modules per row
2 3 4 5 6 7 8 9 10 11 12
AEE Solar
 
AE-50J 48 72 96 106 132 156 180 192 216 240 264
AE-80J, AE-85J , AE-85ET 48  72 96 106 132 156 180 192 216 240 252
AE-100J , AE100ET 60 84 106 132 156 192 216 240 264 288 312
BP Solar BP380, BP485 48 72 96 106 132 156 180 192 216 240 264
BP3125 60 84 106 144 168 192 216 240 276 300 324
BP3160, BP4160, BP4170 72 96 132 156 192 226 252 288 312 348 384
Evergreen EC110, EC115, EC120 60 84 106 132 156 192 216 240 264 288 312
ES170, ES180, ES190, ES200 84 120 156 204 226 276 312 360 384 420  
GE Energy GE65, GE70 48 72 96 106 132 156 180 192 216 240 252
GE50, GE100, GE110 60 84 106 132 156 192 216 240 264 288 312
GE165 84 120 156 192 240 276 312 348 384 432  

Kyocera

KC80, KC130

60 84 106 132 156 192 216 240 264 288 312

KC175GT, KC187GT

84 120 156 204 240 276 312 360 396 432  

KC200GT

84 120 156 204 240 276 324 360 396    

Mitsubishi

MF120UE4N, 125UE4N, 130UE4N

60 84 120 144 168 204 216 240 276 300 324

MF165EB4, 175EB4

72 96 132 168 192 226 252 288 324 348 384

MF175UD4, 180UD4, 185UD4

72 106 144 168 216 240 276 300 336 384 408

Sharp
Solar

NE-80U1

48 72 96 106 132 156 180 192 216 240 252

ND-L3EJE (123 watt)

60 84 106 132 168 192 216 240 264 288 324
ND-167U1, ND-167U3 84 120 168 204 240 288 324 360 396    
NE-165U1, NE-170U1 72 106 132 168 204 240 264 300 336 360 396

SolarWorld

SW80, 85 (Shell SQ80, 85)

48  72 84 106 132 156 168 192 216 240 252
SW 165/175 mono 72 106 132 168 204 226 264 300 324 360 396

Suntech

STP085S

48 72 96 120 132 156 180 204 216 240 264

STP110-12Tb,, 115, 120, 130

60 96 120 144 168 192 216 252 276 300 324

STP110-24Ab, STP175-24Ab1

72 96 132 168 192 226 264 288 324 360 384

TOP

UniRac Top Mounting Sizing Clamp sizes & rail set lengths

Use this chart to determine the size of top mounting clamps for your
modules and the length of the rails required for your array. When sizing
is complete, rails, clamps, splices, and L-feet may be ordered in kits that
contain just the right quantities for a given installation or in bulk packaging
(Pro-Paks).

All UniRac components have a 10-year product warranty and a 5-year finish warranty.
 

Module Brand and Model

Clamp
Size
Rail length (inches) by number of modules per row
2 3 4 5 6 7 8 9 10 11 12
BP Solar BP380, BP485 E 48 72 96 120 144 156 180 192 216 240 252
BP3125 E 60 96 20 144 168 204 226 252 288 312 336
BP3160, BP4160, BP4170 E 72 106 132 168 204 240 264 300 324 360 396
Evergreen EC110, EC115, EC120 C 60 84 120 144 168 192 216 252 276 300 324
ES170, ES180, ES190, ES200 K 84 120 156 204 240 276 312 360 396    
GE Energy GE65, GE70 C 48 72 96 120 144 156 180 204 226 252 264
GE50, GE100, GE110 C 60 84 120 144 168 192 226 252 276 300 336
GE165 C 84 132 168 204 240 288 324 360 396    

Kyocera

KC50, KC65, KC85, KC130

C

60 84 120 144 168 192 216 252 276 300 324

KC167G, KC187G, KC200G

C 84 132 168 204 252 288 324 372 408    

Mitsubishi

MF120EC3,

F 60 84 120 144 168 192 216 240 276 300 324

MF165EB4, 170EB4

F 72 106 132 168 204 240 264 300 336 360 396

MF175UD4, 180UD4, 185UD4

F 72 106 144 180 216 240 276 312 348 384 420

Sanyo

HIT-190, 200, 205, 210

H

84 120 156 192 226 264 300 336 372 408  

Sharp
Solar

NE-80U1

C 48 72 96 120 144 156 180 204 226 252 276

ND-L3EJE (123 watt)

F 60 84 120 144 168 192 226 252 276 300 336
ND-167U1, ND-167U3 G 84 132 168 216 252 288 336 372 408    
NE-175U1, NE-170U1 F 72 106 144 180 204 240 276 312 348 372 408
ND-200U1, ND-208U1, ND-208U1F F 84 132 168 216 252 288 336 376 408    

SolarWorld

SW80, 85 (Shell SQ80, 85)

C 48  72 96 120 144 156 180 204 226 252 264
SW 165/175 mono/P D 72 106 144 168 204

240

276 300 336 372 408
SW 165/175 mono C 72 106 144 168 204 240 276 300 336 372 408

SunPower

SW80, 85 (Shell SQ80, 85)

F 48  72 96 120 144 156 180 204 226 252 264
SW 165/175 mono F 72 106 132 168 204

240

264 300 336 360 396

Suntech

STP085S

B 48 72 96 120 144 168 192 204 226 252 276

STP110-12Tb,, 115, 120, 130

C 60 96 120 144 168

204

226 252 288 312 336

STP110-24Ab, STP175-24Ab1

E 72 106 144 168 204 240 276 300 336 372 396

TOP

UniRac SolarMount Standard Rail and Light Rail Kits

Each kit mounts a single row of modules and consists of rails plus L-feet and hardware to attach feet to rails. Splice bars are also included in four-rail kits. To determine row lengths required for your installation, see the sizing chart on this page for arrays with
top mounting clamps, or above on page 29 for arrays with bottom mounting clips. Rails, L-feet, and splices are clear-anodized.

Easy handling Light Rail saves aluminum and expense without compromising structural integrity. Install an array flush to a roof
or other mounting surface with footings up to 48 inches apart. Mount rails parallel or perpendicular to rafters.

Where foot spacing must exceed 48 inches, Standard Rail provides the extra strength needed. Install an array flush to a roof or
other mounting surface in high profile (rails parallel to rafters) or low profile.

With both Light and Standard Rail, there are accessories to handle special circumstances, such as Spanish tile or an uneven roof.

2-rail kits in lengths up to 216 inches

Each kit contains two rail segments equal to the row length, L-feet, and hardware to join L-feet to rails.

Rail kits 106 inches and shorter ship by UPS. Longer rail sets ship by truck freight. To make up long rail kits that are UPS shippable, use two rail kits of 106 inches or less plus a splice
.
See above tables to determine the rail length required for modules being mounted.

Two-rail UniRac SolarMount kits – L-feet included
Rail
Length
(in)
Standard Rail Light Rail
UniRac
part no
 No. of
L-feet
Ship wt.
(lbs)
Item code  Price Purchase UniRac
part no
 No. of
L-feet
Ship wt.
(lbs)
Item code  Price Purchase
48 300201 4 13 14.1020 $105 303201 4  9 14.3101 $83
60 300202 4 14 14.1024 $121 303202 4 10 14.3103 $94
72  300203 4 16 14.1028 $138 303203 4  11 14.3105 $105
84 300204 17 14.1032  $154 303204 4 12 14.3107 $118
96  300205 4 19 14.1036 $170 303205 6 13 14.3109 $127
106  300206 4  20 14.1040 $186 303206 6 14 14.3111 $138
120 300207  6 22 14.1044 $207 303207 6 15 14.3113 $149
132  300208 6 24 14.1048 $223 303208 16 14.3115 $160
144 300209 25 14.1052 $239 303209 8  17 14.3117 $170
156  300210 6 27 14.1056 $255 303210 18 14.3119 $180
168  300211 6  28 14.1060 $271 303211 8 19 14.3121 $193
180  300212 6 30 14.1064 $293 303212 10  20 14.3123 $204
192  300213 8 31 14.1068 $309 303213 10 21 14.3225 $215
204 300214 33 14.1072 $325 303214 10 22 14.3127 $225
216 300215 8 34 14.1076 $340 303215 10  23 14.3129 $235

TOP

4-rail kits for long rows

Each kit contains four rail segments, two splices, L-feet, and hardware to join L-feet to rails. Rail segments and splices assemble into two spliced rails equal to the row length.

These kits ship via truck freight only.

 
Four-rail UniRac SolarMount kits – L-feet included
Rail
Length
(in)
Segment
length
Standard Rail Light Rail
UniRac
part no.
No. of
L-feet
Ship wt
(lbs)
Item
code
Price Purchase UniRac
part no.
No. of
L-feet
Ship wt
(lbs)
Item
code
Price Purchase
226 106/120 300224 10 40 14.1000 $373 303216 12  28 14.3131 $273
240  120/120 

300225

10 42 14.1001 $389 303217 12 29 14.3133 $284
252 132/120 300226 10  44 14.1002 $405 303218 12  31 14.3135 $295
264  132/132 300227 10 46 14.1003 $416 303219 14 32 14.3137 $306
276  144/132 300228 10  47 14.1004 $432 303220 14 33 14.3139 $317
288 144/144  300229 10 48 14.1005 $448 303221 14  34 14.3141 $328
300  156/144 300230 12 50 14.1006 $469 303222 16  35 14.3143 $339
312 156/156 300231 12  52 14.1007 $485 303223 16 36 14.3145 $350
324  168/156 300232 12 53 14.1008 $501 303224 16 37 14.3147 $361
336 168/168 300233 12  54