|
Solar-Catalog.com 2008
UniRac PV SolarMount
(575) 751-0620
Catalog Contents
SolarTaos.com
PLEASE NOTE, THAT AS OF MAY
1, 2008 UNI-RACK HAD RAISED THEIR PRICES
AND THESE INCREASES MAY OR MAY NOT BE REFLECTED IN OUR BELOW PRICES.
THIS PAGE WILL BE BROUGHT UP TO DATE AS I FIND TIME. THANK YOU FOR YOUR
UNDERSTANDING, TERRY
|
|
|
|
UNIRAC SOLARMOUNT
|
UniRac’s SolarMount is a fast, easy, safe way to
install a PV array in vi rtually
any roof or ground installation. Bottom mounting clips and tilt legs
supplement traditional top mounting clamps. As a result, the system
accommodates the widest variety of installations and assembly preferences –
on the roof and on the ground. Any framed module sold in North America
can be mounted using SolarMount.
Lower-cost SolarMount Light Rail employs 38 percent less aluminum
than SolarMount Standard Rail, yet it’s more than strong enough for flush
applications. Use the same top mounting clamps and footing components that
make SolarMount Standard Rail so easy to install.
Once you’ve selected the PV modules and planned your installation
layout, you’re ready to choose SolarMount components. The chart on the
following page shows what components to use if you are bottom-mounting the
modules. The chart on page 30 shows what parts to use if you are
top-mounting the modules. If you need tilt legs for the mounts, see the
explanation on pages 36-37. Rail and parts to complete your mounting system
can be found on pages 31 to 34.
When sizing is complete, rails, splices, and L-feet may be ordered in
two ways: In kits or in bulk. 2- and 4-rail kits on page 31 contain just the
right quantities of each component for a given installation.
The 8-piece bulk rail bundles on page 32 require 4 bottom-mounting
clips (page 33) for every module to be mounted, and the addition of L-feet
and splices when necessary. |
|
|
|
UniRac SolarMount rails can
be mounted vertically or horizontally
|

|
|
Choose a Top-Mounting or Bottom-Mounting System
On pitched roofs, mount rails either parallel
or perpendicular to the rafters Assembly sequence is a common
determining
factor. Select top-mounting clamps if you prefer to install
modules last – after you’ve attached rails to installed
footings.
This sequence is especially convenient with modules that have
Multi-Connect cables. Select bottom mounting clips if you
plan to attach modules to rails prior to final installation.
This sequence is well suited for modules that must be pre-wired.
Bottom-mounting clips use space more efficiently because they do
not require the 1" space between modules needed by
top clamps.
The use of top-mounting clamps is generally easier when
flush-mounting to a roof. Always use top-mounting clamps
when flush mounting to standoffs. If using bottom-mounting
clamps with L-feet, follow the installation manual carefully
to make sure footing slots are accessible during final
installation.
In roof mounts, when using top-mounting clamps, no extra roof
bracing is needed since rails or mounting feet can be
adjusted to match rafter spacing. With bottom-mounting clamps,
spacing between the rails depends on spacing between
the mounting holes of your particular PV module, and it is
unlikely that they will match rafter spacing. In that case,
place
a stringer over the roof or mounting blocks beneath it. Never
attach footings to the sheathing alone – such an arrangement
will not meet code and will leave the installation and roof
vulnerable to severe damage from wind.
|

UniRac
Bottom Mounting Sizing –
Rail set lengths
This chart lists the length of the
rails required for many common modules.
If you need rail sizing for a module not listed below, please contact us.
|
Module Brand
and Model |
Rail length (inches) by number of modules per row |
|
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
AEE Solar
|
AE-50J |
48
|
72 |
96 |
106 |
132 |
156 |
180 |
192 |
216 |
240 |
264 |
|
AE-80J, AE-85J , AE-85ET |
48
|
72 |
96 |
106 |
132 |
156 |
180 |
192 |
216 |
240 |
252 |
|
AE-100J , AE100ET |
60
|
84
|
106
|
132
|
156
|
192
|
216 |
240 |
264 |
288 |
312 |
|
BP Solar |
BP380, BP485 |
48
|
72 |
96 |
106 |
132 |
156 |
180 |
192 |
216 |
240 |
264 |
|
BP3125 |
60
|
84
|
106
|
144
|
168 |
192
|
216 |
240 |
276 |
300 |
324 |
|
BP3160, BP4160, BP4170 |
72 |
96 |
132 |
156 |
192 |
226 |
252 |
288 |
312 |
348 |
384 |
|
Evergreen |
EC110, EC115, EC120 |
60
|
84
|
106
|
132
|
156
|
192
|
216 |
240 |
264 |
288 |
312 |
|
ES170, ES180, ES190, ES200 |
84 |
120 |
156 |
204 |
226 |
276 |
312 |
360 |
384 |
420 |
|
|
GE Energy |
GE65, GE70 |
48
|
72 |
96 |
106 |
132 |
156 |
180 |
192 |
216 |
240 |
252 |
|
GE50, GE100, GE110 |
60
|
84
|
106
|
132
|
156
|
192
|
216 |
240 |
264 |
288 |
312 |
|
GE165 |
84 |
120 |
156 |
192 |
240 |
276 |
312 |
348 |
384 |
432 |
|
|
Kyocera |
KC80, KC130 |
60
|
84
|
106
|
132
|
156
|
192
|
216 |
240 |
264 |
288 |
312 |
|
KC175GT,
KC187GT |
84 |
120 |
156 |
204 |
240 |
276 |
312 |
360 |
396 |
432 |
|
|
KC200GT |
84 |
120 |
156 |
204 |
240 |
276 |
324 |
360 |
396 |
|
|
|
Mitsubishi |
MF120UE4N,
125UE4N, 130UE4N |
60
|
84
|
120
|
144 |
168 |
204
|
216 |
240 |
276 |
300 |
324 |
|
MF165EB4,
175EB4 |
72 |
96 |
132 |
168 |
192 |
226 |
252 |
288 |
324 |
348 |
384 |
|
MF175UD4,
180UD4, 185UD4 |
72
|
106
|
144
|
168
|
216 |
240 |
276 |
300 |
336 |
384 |
408 |
|
Sharp
Solar |
NE-80U1 |
48
|
72 |
96 |
106 |
132 |
156 |
180 |
192 |
216 |
240 |
252 |
|
ND-L3EJE (123
watt) |
60
|
84
|
106 |
132 |
168 |
192
|
216 |
240 |
264 |
288 |
324 |
|
ND-167U1, ND-167U3 |
84 |
120 |
168 |
204 |
240 |
288 |
324 |
360 |
396 |
|
|
|
NE-165U1, NE-170U1 |
72
|
106
|
132
|
168
|
204 |
240 |
264 |
300 |
336 |
360 |
396 |
|
SolarWorld |
SW80, 85 (Shell
SQ80, 85) |
48
|
72 |
84 |
106 |
132 |
156 |
168 |
192 |
216 |
240 |
252 |
| SW 165/175 mono
|
72
|
106
|
132
|
168
|
204 |
226 |
264 |
300 |
324 |
360 |
396 |
|
Suntech |
STP085S |
48
|
72 |
96 |
120 |
132 |
156 |
180 |
204 |
216 |
240 |
264 |
|
STP110-12Tb,,
115, 120, 130 |
60 |
96 |
120 |
144 |
168 |
192 |
216 |
252 |
276 |
300 |
324 |
|
STP110-24Ab,
STP175-24Ab1 |
72 |
96 |
132 |
168 |
192 |
226 |
264 |
288 |
324 |
360 |
384 |
TOP
|
UniRac
Top Mounting Sizing –
Clamp sizes & rail set lengths
Use this chart to determine the size of top mounting
clamps for your
modules and the length of the rails required for your array. When sizing
is complete, rails, clamps, splices, and L-feet may be ordered in kits that
contain just the right quantities for a given installation or in bulk
packaging
(Pro-Paks).
All UniRac components
have a 10-year product warranty and a 5-year finish warranty.
|
Module Brand
and Model |
Clamp
Size |
Rail length (inches) by number of modules per row |
| 2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
|
BP Solar |
BP380, BP485
|
E |
48
|
72 |
96 |
120 |
144 |
156 |
180 |
192 |
216 |
240 |
252 |
| BP3125
|
E |
60
|
96 |
20
|
144
|
168 |
204 |
226 |
252 |
288 |
312 |
336 |
| BP3160, BP4160, BP4170
|
E |
72 |
106 |
132 |
168 |
204 |
240 |
264 |
300 |
324 |
360 |
396 |
|
Evergreen |
EC110, EC115, EC120 |
C |
60
|
84
|
120 |
144 |
168 |
192
|
216 |
252 |
276 |
300 |
324 |
| ES170, ES180, ES190, ES200
|
K |
84 |
120 |
156 |
204 |
240 |
276 |
312 |
360 |
396 |
|
|
|
GE Energy |
GE65, GE70 |
C |
48
|
72 |
96 |
120 |
144 |
156 |
180 |
204 |
226 |
252 |
264 |
| GE50, GE100, GE110 |
C |
60
|
84
|
120 |
144 |
168 |
192
|
226 |
252 |
276 |
300 |
336 |
| GE165 |
C |
84 |
132 |
168 |
204 |
240 |
288 |
324 |
360 |
396 |
|
|
|
Kyocera |
KC50, KC65, KC85, KC130 |
C |
60
|
84
|
120
|
144 |
168 |
192
|
216 |
252 |
276 |
300 |
324 |
|
KC167G,
KC187G, KC200G |
C |
84 |
132 |
168 |
204 |
252 |
288 |
324 |
372 |
408 |
|
|
|
Mitsubishi |
MF120EC3,
|
F |
60
|
84
|
120
|
144 |
168 |
192 |
216 |
240 |
276 |
300 |
324 |
|
MF165EB4,
170EB4 |
F |
72 |
106 |
132 |
168 |
204 |
240 |
264 |
300 |
336 |
360 |
396 |
|
MF175UD4,
180UD4, 185UD4 |
F |
72 |
106
|
144
|
180 |
216 |
240 |
276 |
312 |
348 |
384 |
420 |
|
Sanyo |
HIT-190, 200,
205, 210 |
H |
84
|
120 |
156 |
192 |
226 |
264 |
300 |
336 |
372 |
408 |
|
|
Sharp Solar |
NE-80U1 |
C |
48
|
72 |
96 |
120 |
144 |
156 |
180 |
204 |
226 |
252 |
276 |
|
ND-L3EJE (123
watt) |
F |
60
|
84
|
120 |
144 |
168 |
192
|
226 |
252 |
276 |
300 |
336 |
| ND-167U1, ND-167U3 |
G |
84 |
132 |
168 |
216 |
252 |
288 |
336 |
372 |
408 |
|
|
| NE-175U1, NE-170U1 |
F |
72
|
106
|
144 |
180 |
204 |
240 |
276 |
312 |
348 |
372 |
408 |
| ND-200U1,
ND-208U1, ND-208U1F |
F |
84 |
132 |
168 |
216 |
252 |
288 |
336 |
376 |
408 |
|
|
|
SolarWorld |
SW80, 85 (Shell
SQ80, 85) |
C |
48
|
72 |
96 |
120 |
144 |
156 |
180 |
204 |
226 |
252 |
264 |
| SW 165/175 mono/P |
D |
72 |
106 |
144 |
168 |
204 |
240 |
276 |
300 |
336 |
372 |
408 |
| SW 165/175 mono |
C |
72 |
106 |
144 |
168 |
204 |
240 |
276 |
300 |
336 |
372 |
408 |
|
SunPower |
SW80, 85 (Shell
SQ80, 85) |
F |
48
|
72 |
96 |
120 |
144 |
156 |
180 |
204 |
226 |
252 |
264 |
| SW 165/175 mono
|
F |
72 |
106 |
132 |
168 |
204 |
240 |
264 |
300 |
336 |
360 |
396 |
|
Suntech |
STP085S |
B |
48
|
72 |
96 |
120 |
144 |
168 |
192 |
204 |
226 |
252 |
276 |
|
STP110-12Tb,,
115, 120, 130 |
C |
60 |
96 |
120 |
144 |
168 |
204 |
226 |
252 |
288 |
312 |
336 |
|
STP110-24Ab,
STP175-24Ab1 |
E |
72 |
106 |
144 |
168 |
204 |
240 |
276 |
300 |
336 |
372 |
396 |
TOP |
|
UniRac SolarMount
Standard Rail and Light Rail
Kits
Each kit mounts a single row of modules and consists
of rails plus L-feet and hardware to attach feet to rails. Splice bars are
also included in four-rail kits. To determine row lengths required for your
installation, see the sizing chart on this page for arrays with
top mounting clamps, or above on page 29 for arrays with bottom mounting
clips. Rails, L-feet, and splices are clear-anodized.
Easy handling Light Rail saves aluminum and expense without
compromising structural integrity. Install an array flush to a roof
or other mounting surface with footings up to 48 inches apart. Mount rails
parallel or perpendicular to rafters.
Where foot spacing must exceed 48 inches, Standard Rail provides the
extra strength needed. Install an array flush to a roof or
other mounting surface in high profile (rails parallel to rafters) or low
profile.
With both Light and Standard Rail, there are accessories to handle
special circumstances, such as Spanish tile or an uneven roof.
2-rail kits in lengths
up to 216 inches
Each kit contains two rail segments
equal to the row length, L-feet, and
hardware to join L-feet to rails.
Rail kits 106 inches and shorter ship by UPS. Longer rail sets ship
by truck freight. To make up long
rail kits that are UPS shippable, use
two rail kits of 106 inches or less plus a splice
.
See above tables to
determine the rail length required
for modules being mounted.
|
Two-rail UniRac SolarMount kits – L-feet included |
Rail
Length
(in) |
Standard Rail |
Light Rail |
UniRac
part no |
No. of
L-feet |
Ship wt.
(lbs)
|
Item code |
Price |
Purchase |
UniRac
part no |
No. of
L-feet |
Ship wt.
(lbs)
|
Item code |
Price |
Purchase |
|
48
|
300201
|
4
|
13
|
14.1020
|
$105
|
 |
303201
|
4 |
9
|
14.3101
|
$83 |
 |
|
60
|
300202
|
4
|
14
|
14.1024
|
$121
|
 |
303202
|
4
|
10
|
14.3103
|
$94 |
 |
|
72 |
300203 |
4 |
16 |
14.1028 |
$138 |
 |
303203 |
4 |
11 |
14.3105 |
$105 |
 |
|
84 |
300204 |
4 |
17 |
14.1032 |
$154 |
 |
303204 |
4 |
12 |
14.3107 |
$118 |
 |
|
96 |
300205 |
4 |
19 |
14.1036 |
$170 |
 |
303205 |
6 |
13 |
14.3109 |
$127 |
 |
|
106 |
300206 |
4 |
20 |
14.1040 |
$186 |
 |
303206 |
6 |
14 |
14.3111 |
$138 |
 |
|
120 |
300207 |
6 |
22 |
14.1044 |
$207 |
 |
303207 |
6 |
15 |
14.3113 |
$149 |
 |
|
132 |
300208 |
6 |
24 |
14.1048 |
$223 |
 |
303208 |
8 |
16 |
14.3115 |
$160 |
 |
|
144 |
300209 |
6 |
25 |
14.1052 |
$239 |
 |
303209 |
8 |
17 |
14.3117 |
$170 |
 |
|
156
|
300210
|
6
|
27
|
14.1056
|
$255 |
 |
303210
|
8
|
18 |
14.3119
|
$180 |
 |
|
168
|
300211
|
6 |
28
|
14.1060
|
$271 |
 |
303211
|
8
|
19
|
14.3121
|
$193 |
 |
|
180
|
300212
|
6
|
30
|
14.1064
|
$293 |
 |
303212
|
10 |
20
|
14.3123
|
$204 |
 |
|
192
|
300213
|
8
|
31
|
14.1068
|
$309 |
 |
303213
|
10
|
21
|
14.3225
|
$215 |
 |
|
204
|
300214
|
8
|
33 |
14.1072
|
$325
|
 |
303214
|
10
|
22
|
14.3127
|
$225 |
 |
|
216
|
300215
|
8
|
34
|
14.1076
|
$340 |
 |
303215
|
10 |
23
|
14.3129
|
$235 |
 |
TOP
|
4-rail kits for long
rows
Each kit contains four
rail segments, two
splices, L-feet, and
hardware to join L-feet
to rails. Rail segments
and splices assemble
into two spliced rails
equal to the row length.
These kits ship via truck
freight only.
| |