The FLEXmax family of charge controllers is the latest innovation in
Maximum Power Point Tracking (MPPT) charge controllers from OutBack Power
Systems. The innovative FLEXmax MPPT software algorithm is both continuous
and active, increasing your photovoltaic array power yield up to 30%
compared to non-MPPT controllers. Thanks to active cooling and intelligent
thermal management cooling, both FLEXmax charge controllers can operate at
their full maximum current rating, 60 Amps or 80 Amps respectively, in
ambient temperatures as high as 104°F (40°C). The integrated OutBack network communications allows FLEXmax
series Charge Controllers to be remotely programmed and monitored via a MATE
system display and provides unrivaled complete system integration. |
||||||||||||||||||||||||||||||||
|
TOP |
||||||||||||||||||||||||||||||||
|
TOP |
||||||||||||||||||||||||||||||||
|
OutBack
FLEXmax 60 amp Charge Controller FLEXmaxtm Continuous Maximum Power Point Tracking Charge Controllers
Included in all of the FLEXmax Charge Controllers are the revolutionary features first developed by OutBack Power, including support for a wide range of nominal battery voltages and the ability to step-down a high voltage solar array to recharge a low voltage battery. A built-in back lit 80 character display shows status information and logged system performance data for the last 128 days at the touch of a button. The integrated OutBack network communications allow the FLEXmax series charge controller to be remotely programmed and monitored via a MATE system display and provides unrivaled complete system integration. FLEXmax MPPT Charge Controllers are the only choice when you demand a high performance, efficient and versatile charge controller for your advanced power system. FM60 MPPT Charge Controller Specifications: Nominal Battery Voltages: 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) Maximum Output Current: 60 amps @ 104° F (40°C) with adjustable current limit Maximum Solar Array STC Nameplate: 12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts NEC Recommended Solar Array STC Nameplate: 12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts PV Open Circuit Voltage (VOC): 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum Standby Power Consumption: Less than 1 Watt typical Power Conversion Efficiency: 98.1% @ 60 Amps in at 48 VDC System voltage - Typical Charging Regulation: Five Stages: Bulk, Absorption, Float, Silent and Equalization Voltage Regulation Set points: 10 to 60 VDC user adjustable with password protection Equalization Charging: Programmable Voltage Setpoint and Duration - Automatic Termination when completed Battery Temperature Compensation: Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell Voltage Step-Down Capability: Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input Programmable Auxilary Control Output: 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) Status Display: 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total Remote Display and Controller: Optional Mate or Mate2 with RS232 Serial Communications Port Network Cabling: Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) Data Logging: Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production Hydro Turbine Applications: Consult factory for approved Turbines Positive Ground Applications: Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) Operating Temperature Range: Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C) Environmental Rating: Indoor Type 1 Conduit Knockouts: One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom Warranty: Standard 5 year / Available 10 Year Weight - Unit: 11.65 lbs (5.3 kg) Weight - Shipping: 14.55 lbs (6.4 kg) Dimensions - Unit (H x W x D) 13.5 x 5.75 x 4" (40 x 14 x 10 cm) Dimensions - Shipping: 18 x 11 x 8" (46 x 30 x 20 cm) Options: Menu Languages: English & Spanish |
||||||||||||||||||||||||||||||||
|
TOP |
||||||||||||||||||||||||||||||||
OutBack
FLEXmax 80 amp Charge Controller![]() FLEXmaxtm Continuous Maximum Power Point Tracking Charge Controllers
Included in all of the FLEXmax Charge Controllers are the revolutionary features first developed by OutBack Power, including support for a wide range of nominal battery voltages and the ability to step-down a high voltage solar array to recharge a low voltage battery. A built-in back lit 80 character display shows status information and logged system performance data for the last 128 days at the touch of a button. The integrated OutBack network communications allow the FLEXmax series charge controller to be remotely programmed and monitored via a MATE system display and provides unrivaled complete system integration. FLEXmax MPPT Charge Controllers are the only choice when you demand a high performance, efficient and versatile charge controller for your advanced power system. FM80 MPPT Charge Controller Specifications Nominal Battery Voltages: 12, 24, 36, 48, or 60 VDC Maximum Output Current: 80 amps @ 104º F (40ºC) with adjustable current limit Maximum Solar Array STC Nameplate
Standby Power Consumption: Less than 1 Watt typical Power Conversion Efficiency: 97.5% @ 80 Amps in a 48 VDC System - Typical Charging Regulation: Five Stages: Bulk, Absorption, Float, Silent and Equalization Voltage Regulation Set points: 10 to 80 VDC user adjustable with password protection Equalization Charging: Programmable Voltage Set point and Duration & Automatic Termination Battery Temperature Compensation: Automatic with optional RTS 5.0 mV per °C per 2V battery cell Voltage Step-Down Capability: Max 150 VDC input PV array can charge a lower voltage battery Programmable Auxiliary Control Output:12 VDC (0.2 amp max) programmable output signal Status Display: 3.1” (8 cm) back lit LCD screen - 4 lines with 80 alphanumeric characters total Remote Display and Controller: Optional Mate or Mate2 with RS232 Serial Communications Port Network Cabling: Proprietary CAT 5e Cable (8 wires) with RJ 45 Modular Connectors Data Logging: Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production Hydro Turbine Applications: Consult factory for approved Turbines Positive Ground Applications: Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) Operating Temperature Range: Minimum -40° to maximum 60° C Environmental Rating: Indoor Type 1 Conduit Knockouts: One 1” (35mm) on the back; One1” (35mm) on the left side; Two 1” (35mm) on the bottom Menu Languages: English & Spanish Warranty: Standard 5 year Weight Unit: 12.20 lbs (5.56 kg) Dimensions Unit: 16.25” x 5.75” x 4” (41.3 x 14 x 10 cm) - (H x W x D) Shipping Weight: 15.75 lbs (7.10 kg) Shipping Dimensions: 21” x 10.5” x 9.75” (53 x 27 x 25 cm) Options |
||||||||||||||||||||||||||||||||
|
TOP |
||||||||||||||||||||||||||||||||
|
All transactions made on
this site are secure and Hacker Safe.
Prices in this catalog subject to change without notice. |
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||