AIR CONDITIONERS APPLIANCES AUTOTRANSFORMERS BACKPACKS BATTERIES, STORAGE BATTERY ACCESSORIES BATTERY CABLES BATTERY CHARGERS BATTERY CONTAINERS BOOKS CHARGE CONTROLLERS CIRCUIT BREAKERS COMPOSTERS COMPOSTING TOILETS DEHUMIDIFIERS DISCONNECTS ELECTRICAL SUPPLIES FANS FUSES & HOLDERS FREEZERS GARDEN COMPOSTERS GENERATORS, BACKUP GENERATOR STARTERS GROUNDING PRODUCTS HUMIDIFIERS INVERTERS -GRID-TIE -GRID INTERACTIVE -OFF GRID, MODIFIED SINE -OFF GRID, SINEWAVE -PORTABLE LIGHTING LIGHTNING PROTECTION LIGHTING CONTROLLERS LOAD DIVERSION METERS MICRO HYDROPOWER MONITORING SYSTEMS PV MOUNTING STRUCTURES RANGES PORTABLE POWER REFRIGERATION SKYLIGHTS, TUBLAR SOLAR PV MODULES SOLAR WATER HEATING STABER WASHERS STOVES TOILETS, COMPOSTING TRANSFORMERS USED ITEMS VENTILATION WASHING MACHINES WATER PUMPS WATER HEATERS, TANKLESS WIND POWER WIRE |
Square-D 240 and 600 Volt Nema 3R Safety Switch Disconnects![]() According to the National Electric Code, section 690.15, PV arrays must have a disconnecting means to isolate the inverter from the PV power source. Utility intertie inverters that utilize PV arrays with voltages above 250VDC require a disconnect rated for 600VDC to perform this function. The Square-D 600 VDC 30 amp 3-pole safety switches are UL listed to handle 13A at 600VDC per pole. They can be used for disconnecting up to three PV arrays for three grid-tie inverters. It has wiring lugs that are rated to accept two #14 to #10 wires in each lug. This allows the disconnect switch to also act as a string combiner in systems that utilize two strings of PV modules per inverter. All other Square D 600 VDC disconnects are rated for disconnecting one string at full rated power. Many utilities require an AC disconnect between an intertie inverter and the AC load center, close to the AC service entrance, with a visible and lockable handle. A 30 amp 240 volt disconnect is good for up to 5kW at 240 VAC (one or two 2500W intertie inverters) and the 60 amp disconnect is good for up to 12.5kW (three to five 2500W intertie inverters). For connection of multiple inverters to one of these disconnects, use an AC load center, with a circuit breaker for each inverter installed, as an AC combiner box between the inverters and the disconnect switch. The breakers can be back-fed with the inverter outputs and the load center main lugs will handle the combined outputs to be connected to the AC disconnect. Use Class-R fuses of the proper amperage for fused disconnects. Use the hubs on the next page to connect conduit or a kWh meter socket to the top of the disconnect. Disconnects are raintight (NEMA 3R) for outdoor use. Order the neutral bus bar and ground bus bar if you need to land these conductors in the disconnect switch box. See next page for accessories. |
||||||||||||||||||||
|
Square D Disconnect Accessories Field installable service ground and neutral bus bars and hubs for the safety disconnect switches on the previous page. See table to determine which neutral and ground to use. |
|||||||||||||||||||||
Class R Fuses
![]() ![]() ![]() These Class-R fuses can be used in AC circuits up to 250V or DC circuits up to 125V. They have the high amp interrupting capacity (AIC) required for fusing circuits powered by batteries and for protecting Square-D brand circuit breakers. They can be be used to protect wiring to small inverters (100-700 watts) and wiring from charging sources. Use these fuses in fused safety disconnect switches on the previous page and in the fuse blocks at right. UL listed |
|||||||||||||||||||||
Class R Fuse Blocks![]() Use these fuse blocks with the Class-R 250 volt fuses. Bare wire ends fit into the screw terminals on each end of the fuse block. The small fuse block holds 10-30A fuses and accepts up to #2 wire. The medium size block holds 40-60A fuses and accepts up to #2 wire also. The large size block holds a 100A fuse and accepts up to #1/0 wire. Small and medium size blocks are available in one or two pole versions. |
|||||||||||||||||||||
Inline ATC Fuse Holder
![]() The waterproof cover makes this an excellent choice to fuse a single circuit, indoors or out. Cut wire loop and splice into the line to be protected. We recommend these with 1 amp fuses below in the positive power line for Trimetric, Link and Trace TM500A meters. Low voltage DC use only.
|
|||||||||||||||||||||
ATC Fuses
![]() ATC blade-type fuses were designed for low voltage DC circuits for the automotive industry. They are very popular in autos and RVs. They are not approved by the National Electrical Code for use in homes, but they are often used to provide circuit protection in remote cabin power systems. They are sold in boxes of 10 fuses. |
|||||||||||||||||||||
|
DC OVERCURRENT PROTECTION |
|||||||||||||||||||||
Xantrex DC Disconnect![]() The Xantrex DC Disconnect is a white, powder-coated indoor enclosure with conduit knockouts for connection to inverters, batteries, DC charging sources, charge controllers and DC load centers. It comes with one 175A or 250A circuit breaker for an inverter (with space for a second breaker for a second inverter - order separately) that meets the National Electric Code requirements for disconnection and overcurrent protection of battery-based power systems. There are knockouts on the sides for four 15 to 100 amp DC breakers used for charging sources and DC loads. Use the DC Bonding Block (DCBB - order separately below) for connecting the negative cables and for single-point DC system grounding. There are pre-drilled places inside for two metering shunts. Knock-outs on the top are provided for mounting two Xantrex C-Series or OutBack MX-60 PV charge controllers, or one RVPP Solar Boost PV charge controller. Knockouts on the sides are designed for mounting two Xantrex SW, SW-Plus, or DR inverter/chargers with their optional conduit boxes and 2" offset nipples. Order 175A or 250A DC surface mount circuit breakers listed below for adding second inverter breaker. Order 15A to 100A DC panel mount circuit breakers to use in the DC Disconnect side spaces. Use the DC175 for the Xantrex SW4048, SW-Plus 2524 & 2548, DR1512, DR1524, and DR2424 inverters. Use the DC250 for the Xantrex SW4024, SW5548, DR2412, and DR2436 inverters. ETL listed to UL508. Dimensions: 21""H x 10.5""W x 5""D. Weight: 14 lbs
|
|||||||||||||||||||||
|
DC Circuit Breakers These single pole circuit breakers are UL listed for use in DC circuits with voltages up to 125VDC. They are commonly used in DC power centers as overcurrent protection and disconnecting means between PV arrays and charge controllers, between charge controllers and batteries, between other DC charging sources (such as wind and hydro generators) and batteries, and as outputs to DC loads. They have the high amp interrupting capacity (AIC) needed between batteries and Square-D QO and QOU circuit breakers and load centers for 12V and 24V systems. Breakers are Heinneman, Airpax, or Carlingswitch brand. They are available in two different configurations: |
|||||||||||||||||||||