Square-D 240 and 600 Volt Nema 3R Safety Switch Disconnects
According to the National Electric PART NUMBER , section 690.15, PV arrays must have
a disconnecting means to isolate the inverter from the PV power source.
Utility intertie inverters that utilize PV arrays with voltages above 250VDC
require a disconnect rated for 600VDC to perform this function. The Square-D
600 VDC 30 amp 3-pole safety switches are UL listed to handle 13A at 600VDC
per pole. They can be used for disconnecting up to three PV arrays for three
grid-tie inverters. It has wiring lugs that are rated to accept two #14 to
#10 wires in each lug. This allows the disconnect switch to also act as a
string combiner in systems that utilize two strings of PV modules per
inverter. All other Square D 600 VDC disconnects are rated for disconnecting
one string at full rated power.
Many utilities require an AC disconnect between an intertie inverter and
the AC load center, close to the AC service entrance, with a visible and
lockable handle. A 30 amp 240 volt disconnect is good for up to 5kW at 240
VAC (one or two 2500W intertie inverters) and the 60 amp disconnect is good
for up to 12.5kW (three to five 2500W intertie inverters). For connection of
multiple inverters to one of these disconnects, use an AC load center, with
a circuit breaker for each inverter installed, as an AC combiner box between
the inverters and the disconnect switch. The breakers can be back-fed with
the inverter outputs and the load center main lugs will handle the combined
outputs to be connected to the AC disconnect.
Use Class-R fuses of the proper amperage for fused disconnects. Use the
hubs on the next page to connect conduit or a kWh meter socket to the top of
the disconnect. Disconnects are raintight (NEMA 3R) for outdoor use. Order
the neutral bus bar and ground bus bar if you need to land these conductors
in the disconnect switch box. See next page for accessories.
|
|
Amps |
AC / DC |
Fused |
Poles |
Neutral Kit |
Ground Kit |
Dimensions (in.) H x W x D |
Weight (lbs.) |
Square-D Model |
PART NUMBER
|
OUR PRICE |
Purchase |
|
600 Volt AC or DC 3 Pole NEMA 3R Heavy Duty Switches |
|
30 |
Yes |
No |
3* |
SN03 |
GTK03 |
14.88 x 6.63 x 4.88 |
9.3 |
HU361RB |
053-02312 |
$165 |
 |
|
30 |
Yes |
Yes |
3* |
SN03 |
GTK03 |
14.88 x 6.63 x 4.88 |
9.8 |
H361RB |
053-02313 |
$268 |
 |
|
* Uses 2 poles in series
for 600VDC, except for pv where all 3 poles may be used for 600 VDC at
13 amps per pole |
|
60 |
Yes |
No |
3** |
SN0610 |
GTK0610 |
17.50 x 9.00 x 6.38 |
16 |
HU362RB |
053-02339 |
$260 |
 |
|
60 |
Yes |
Yes |
3** |
SN0610 |
GTK0610 |
17.50 x 9.00 x 6.38 |
16 |
H362RB |
053-02341 |
$315 |
 |
|
100 |
Yes |
No |
3** |
SN0610 |
GTK0610 |
21.25 x 8.50 x 6.38 |
24 |
HU363RB |
053-02357 |
$655 |
 |
|
100 |
Yes |
Yes |
3** |
SN0610 |
GTK0610 |
21.25 x 8.50 x 6.38 |
24 |
H363RB |
053-02355 |
$829 |
 |
|
200 |
Yes |
No |
3** |
SN20A |
PKOGTA2 |
29.25 x 17.25 x 8.50 |
44 |
HU364RB |
053-02364 |
$728 |
 |
|
200 |
Yes |
Yes |
3** |
SN20A |
PKOGTA2 |
29.25 x 17.25 x 8.50 |
44 |
H364RB |
053-02374 |
$838 |
 |
|
** Uses 2 poles (and 2
fuses) in series for 600VDC |
|
240 Volt AC / 125 Volt DC*** NEMA 3R Heavy Duty
Switches |
|
30 |
Yes |
Yes |
3 |
Included |
GTK03 |
14.88 x 6.63 x 4.88 |
9.8 |
H321NRB |
053-02315 |
$314 |
 |
|
60 |
Yes |
Yes |
3 |
Included |
GTK03 |
14.88 x 6.63 x 4.88 |
10 |
H322NRB |
053-02336 |
$503 |
 |
|
100 |
Yes |
Yes |
3 |
Included |
GTK0610 |
21.25 x 8.50 x 6.38 |
19 |
H323NRB |
053-02351 |
$722 |
 |
|
200 |
Yes |
Yes |
3 |
Included |
PKOGTA2 |
29.25 x 17.25 x 8.50 |
43 |
H324NRB |
053-02363 |
$988 |
 |
|
*** Switches are rated
for 250VDC but available fuses are only rated for 125VDC |
|
240 Volt AC only NEMA 3R General Duty Switches |
|
30 |
AC Only |
No |
2 |
N/A |
PK3GTA1 |
9.63 x 7.25 x 3.75 |
4.4 |
DU221RB |
053-02318 |
$83 |
 |
|
30 |
AC Only |
Yes |
2 |
Included |
PK3GTA1 |
9.63 x 7.25 x 3.75 |
4.5 |
D221NRB |
053-02326 |
$90 |
 |
|
30 |
AC Only |
No |
3 |
N/A |
PK3GTA1 |
9.63 x 7.25 x 3.75 |
4.7 |
DU321RB |
053-02319 |
$139 |
 |
|
30 |
AC Only |
Yes |
3 |
Included |
PK3GTA1 |
9.63 x 7.25 x 3.75 |
5.1 |
D321NRB |
053-02329 |
$139 |
 |
|
60 |
AC Only |
Yes |
2 |
Included |
GTK03 |
14.88 x 6.63 x 4.88 |
9.7 |
D222NRB |
053-02334 |
$141 |
 |
|
60 |
AC Only |
No |
3 |
N/A |
PK3GTA1 |
9.63 x 7.25 x 3.75 |
5 |
DU322RB |
053-02342 |
$222 |
 |
|
60 |
AC Only |
Yes |
3 |
Included |
GTK03 |
14.88 x 6.63 x 4.88 |
9.8 |
D322NRB |
053-02343 |
$210 |
 |
|
100 |
AC Only |
Yes |
2 |
Included |
GTK0610 |
17.50 x 8.50 x 6.50 |
16 |
D223NRB |
053-02358 |
$227 |
 |
|
100 |
AC Only |
No |
3 |
N/A |
GTK0610 |
17.50 x 8.50 x 6.50 |
15 |
DU323RB |
053-02359 |
$386 |
 |
|
100 |
AC Only |
Yes |
3 |
Included |
GTK0610 |
17.50 x 8.50 x 6.50 |
16 |
D323NRB |
053-02361 |
$386 |
 |
|
200 |
AC Only |
Yes |
2 |
Included |
PKOGTA2 |
29.25 x 17.25 x 8.25 |
29 |
D224NRB |
053-02371 |
$513 |
 |
|
200 |
AC Only |
Yes |
3 |
Included |
PKOGTA2 |
29.25 x 17.25 x 8.25 |
30 |
D324NRB |
053-02372 |
$853 |
 |
|
|
TOP
|
|
Square D Disconnect Accessories
Field installable service ground and neutral bus bars and hubs for the
safety disconnect switches on the previous page. See table to determine
which neutral and ground to use.
|
Neutral & Ground Accessories |
PART NUMBER
|
OUR PRICE |
Purchase |
|
SN03 Neutral Bus Bar |
053-02389 |
$52 |
 |
|
SN0610 Neutral Bus Bar |
053-02381 |
$71 |
 |
|
SN20ANeutral Bus Bar |
053-02383 |
$133 |
 |
|
GTK03 Ground Bus Bar |
053-02387 |
$8.24 |
 |
|
PK3GTA1 Ground Bus Bar |
053-02395 |
$8 |
 |
|
GTK0610 Ground Bus Bar |
053-02386 |
$13 |
 |
|
PKOGTA2 Ground Bus Bar |
053-02388 |
$38.65 |
 |
|
Conduit Hubs |
PART NUMBER
|
OUR PRICE |
Purchase |
|
Top Mount Hub 3/4" |
053-02305 |
$22 |
 |
|
Top Mount Hub 1" |
053-02306 |
$22 |
 |
|
Top Mount Hub 1-1/4" |
053-02307 |
$22 |
 |
|
Top Mount Hub 1-1/2" |
053-02308 |
$22 |
 |
|
Top Mount Hub 2" |
053-02309 |
$40 |
 |
|
|
TOP
|
|
Square-D QO Load Centers
Square D brand load centers can be used for multiple purposes, for wiring
that meets the National Electric PART NUMBER (NEC). All of these can be used as AC
load centers or sub-panels. Panels using QO plug in breakers are rated up to
50VDC for use as 12V or 24V DC load centers. They can also be used to
combine the AC output from multiple inverters feeding the grid.
When used as DC load centers they should be protected by a high interrupt
capacity fuse or circuit breaker between the load center and the battery.
Use one of the Class T or Class R fuses, or the DC breakers used in the
Outback and Xantrex DC power centers.
When used to combine the AC output of multiple grid tie inverters, and
meet the requirements of NEC 690.64(B)(2) the bus amp rating for the load
center must be larger than the sum of all of the overcurrent devices feeding
it, from both the utility and all inverters.
The 277/480 V load centers can be used to combine the output from
multiple SMA6000U inverters to feed a 277Y/480VAC grid interconnection. One
30A continuous duty breaker is used for each inverter that is set up for
277V hot to neutral.
Load centers are not supplied with any breakers – order breakers
separately (except the 277V breaker on this page).
|
|
120/240
Volt AC Single Phase Main Lug Load Centers |
|
Spaces
(single) |
Bus Amp
Rating |
Outdoor |
Cover
|
Max wire
in main lug |
Ground Kit
for this unit |
Dimensions
(in.) H x W x D |
Weight
(lbs.) |
Square-D
Model |
PART NUMBER |
OUR PRICE |
PURCHASE |
|
2 |
70 |
Yes |
INCL. |
# 4 |
PK4GTA |
9.38 x 4.88 x 4 |
5.0 |
QO24L70RB |
053-02141 |
$60 |
 |
|
2 |
70 |
No |
INCL. |
# 4 |
PK4GTA |
9.30 x 4.81 x 3.19 |
3.8 |
QO24L70S |
053-02144 |
$50 |
 |
|
6 |
100 |
Yes |
INCL. |
# 1 |
PK7GTA |
12.62 x 8.88 x 4.27 |
9.7 |
QO612L100RB |
053-02147 |
$54 |
 |
|
6 |
100 |
No |
INCL. |
# 1 |
PK7GTA |
12.57 x 8.88 x 3.8 |
8.3 |
QO612L100DS |
053-02153 |
$46 |
 |
|
12 |
125 |
Yes |
INCL. |
# 2/0 |
INCL. |
19 x 14.25 x 4.5 |
23 |
QO112L125GRB |
053-02163 |
$190 |
 |
|
12 |
125 |
No |
Add |
# 2/0 |
INCL. |
18 x 14.25 x 3.75 |
15 |
QO112L125G |
053-02162 |
$85 |
 |
|
12 |
200 |
Yes |
INCL. |
250 kcmil |
INCL. |
26.25 x 14.25 x 4.5 |
27 |
QO112L200GRB |
053-02165 |
$320 |
 |
|
12 |
200 |
No |
Add |
250 kcmil |
PK15GTA |
29.86 X 14.25 X 3.75 |
18 |
QO112L200G |
053-02164 |
$177 |
 |
|
Uses QO plug in breakers |
|
120/208 Volt AC Three Phase Main Lug Load Centers |
|
12 |
125 |
Yes |
INCL. |
# 2/0 |
INCL. |
19.00 x 14.25 x 4.52 |
22 |
QO312L125GRB |
053-02181 |
$323 |
 |
|
12 |
125 |
No |
Add |
# 2/0 |
INCL. |
19.00 x 14.25 x 3.75 |
11 |
QO312L125G |
053-02183 |
$221 |
 |
|
18 |
200 |
Yes |
INCL. |
250 kcmil |
INCL. |
30.00 x 14.25 x 4.52 |
31 |
QO318L200GRB |
053-02185 |
$412 |
 |
|
18 |
200 |
No |
Add |
250 kcmil |
INCL. |
30.00 x 14.25 x 3.75 |
17 |
QO318L200G |
053-02187 |
$325 |
 |
|
Uses QO plug in breakers |
|
277/480 Volt AC Three Phase Main Lug Load Centers |
|
12 |
125 |
Yes |
INCL. |
250 kcmil |
PK9GTA |
26.00 x 20.00 x 6.50 |
36 |
NF412L1 (MH26WP) |
053-02191 |
$2,319 |
 |
|
12 |
125 |
No |
INCL. |
250 kcmil |
PK9GTA |
26.00 x 20.00 x 5.75 |
22 |
NF412L1 (MH26,NC26S) |
053-02193 |
$1,264 |
 |
|
30 |
250 |
Yes |
INCL. |
350 kcmil |
PK18GTA |
38.00 x 20.00 x 6.50 |
42 |
NF430L2 (MH38WP) |
053-02195 |
$2,556 |
 |
|
30 |
250 |
No |
INCL. |
350 kcmil |
PK18GTA |
38.00 x 20.00 x 5.75 |
27 |
NF430L2 (MH38,NC38S) |
053-02197 |
$1,603 |
 |
|
Circuit Breaker, single
pole, 277 Volt, 30A continuous duty rated |
1 |
EDB14030 |
053-02111 |
$85 |
 |
|
|
TOP |
|
Square-D Load Center Covers and Ground Bus Bars for Load
Centers |
|
Description |
Weight (lbs) |
Square D Model |
PART NUMBER |
OUR PRICE |
Purchase |
| Surface Cover for 12 space
125A load centers, 053-02162 & 053-02183 |
6.0 |
QOC16US |
053-02159 |
$18.00 |
 |
| Flush Cover for 12 space
125A load centers, 053-02162 & 053-02183 |
7.0 |
QOC16UF |
053-02156 |
$21.50 |
 |
| Surface Cover for all 200A
indoor load centers, 053-02164 & 053-02187 |
9.2 |
QOC30US |
053-02169 |
$58.00 |
 |
| Flush Cover for all 200A
indoor load centers, 053-02164 & 053-02187 |
11 |
QOC30UF |
053-02170 |
$58.00 |
 |
| Ground Bus Bar for 2 space
load centers |
PK4GTA |
053-02390 |
$6.00 |
 |
| Ground Bus Bar for 6 space
load centers |
PK7GTA |
053-02391 |
$7.00 |
 |
| Ground Bus Bar for 12 space
load centers |
PK9GTA |
053-02392 |
$10.00 |
 |
| Ground Bus Bar for 12 space
200A load center |
PK15GTA |
053-02393 |
$23.00 |
 |
| Ground Bus Bar for 30 space
load centers |
PK18GTA |
053-02394 |
$25.00 |
 |
|
|
TOP |
Class R Fuses
   
These Class-R fuses can be used in AC circuits up to 250V or DC circuits up
to 125V. They have the high amp interrupting capacity (AIC) required for
fusing circuits powered by batteries and for protecting Square-D brand
circuit breakers. They can be be used to protect wiring to small inverters
(100-700 watts) and wiring from charging sources. Use these fuses in fused
safety disconnect switches on the previous page and in the fuse blocks at
right. UL listed
|
Amps |
250VAC/125VDC |
600VAC/VDC |
|
PART NUMBER
|
OUR PRICE |
Purchase |
PART NUMBER
|
OUR PRICE |
Purchase |
|
10 |
053-02441 |
$5 |
 |
053-02442 |
$11 |
 |
|
15 |
053-02444 |
$5 |
 |
053-02447 |
$11 |
 |
|
20 |
053-02450 |
$5 |
 |
053-02453 |
$11 |
 |
|
30 |
053-02456 |
$5 |
 |
053-02459 |
$11 |
 |
|
40 |
053-02462 |
$8 |
 |
053-02463 |
$24 |
 |
|
50 |
053-02465 |
$8 |
 |
053-02466 |
$24 |
 |
|
60 |
053-02468 |
$8 |
 |
053-02471 |
$24 |
 |
|
70 |
053-02469 |
$18 |
 |
053-02470 |
$46 |
 |
|
80 |
053-02475 |
$18 |
 |
053-02472 |
$46 |
 |
|
90 |
053-02476 |
$18 |
 |
053-02473 |
$46 |
 |
|
100 |
053-02474 |
$18 |
 |
053-02477 |
$46 |
 |
|
125 |
053-02478 |
$48 |
 |
053-02481 |
$80 |
 |
|
150 |
053-02479 |
$48 |
 |
053-02482 |
$80 |
 |
|
200 |
053-02480 |
$48 |
 |
053-02483 |
$80 |
 |
|
|
TOP |
Class R Fuse Blocks
Use these fuse blocks with the Class-R 250 volt fuses. Bare wire ends fit
into the screw terminals on each end of the fuse block. The small fuse block
holds 10-30A fuses and accepts up to #2 wire. The medium size block holds
40-60A fuses and accepts up to #2 wire also. The large size block holds a
100A fuse and accepts up to #1/0 wire. Small and medium size blocks are
available in one or two pole versions.
|
Description |
PART NUMBER
|
OUR PRICE |
Purchase |
|
Class R Fuse Block
0.1-30A, 1-Pole |
053-02423 |
$5 |
 |
|
Class R Fuse Block
0.1-30A, 2-Pole |
053-02426 |
$12 |
 |
|
Class R Fuse Block
31-60A, 1-Pole |
053-02429 |
$9 |
 |
|
Class R Fuse Block
31-60A, 2-Pole |
053-02432 |
$16 |
 |
|
Class R Fuse Block
61-100A, 1-Pole |
053-02435 |
$25 |
 |
|
|
TOP |
Inline ATC Fuse Holder

The waterproof cover makes this an excellent choice to fuse a single
circuit, indoors or out. Cut wire loop and splice into the line to be
protected. We recommend these with 1 amp fuses below in the positive power
line for Trimetric, Link and Trace TM500A meters. Low voltage DC use only.
|
Description |
PART NUMBER
|
OUR PRICE |
Purchase |
|
ATC Inline Holder 18 awg |
053-02663 |
$3.00 |
 |
|
ATC Inline Holder 10 awg |
053-02669 |
$5.00 |
 |
|
|
TOP |
ATC Fuses

ATC blade-type fuses were designed for low voltage DC circuits for the
automotive industry. They are very popular in autos and RVs. They are not
approved by the National Electrical PART NUMBER for use in homes, but they are
often used to provide circuit protection in remote cabin power systems.
They
are sold in boxes of 10 fuses.
|
Description |
PART NUMBER
|
OUR PRICE |
Purchase |
| ATC Fuse 1A |
053-02629 |
$0.65 |
 |
| ATC Fuse 3A |
053-02631 |
$0.65 |
 |
| ATC Fuse 5A |
053-02633 |
$0.65 |
 |
| ATC Fuse 10A |
053-02635 |
$0.65 |
 |
| ATC Fuse 15A |
053-02637 |
$0.65 |
 |
| ATC Fuse 20A |
053-02639 |
$0.65 |
 |
| ATC Fuse 30A |
053-02641 |
$0.65 |
 |
|
|
TOP |
|
DC OVER CURRENT PROTECTION |
|
Xantrex DC Disconnect
The Xantrex DC Disconnect is a white, powder-coated indoor enclosure with
conduit knockouts for connection to inverters, batteries, DC charging
sources, charge controllers and DC load centers. It comes with one 175A or
250A circuit breaker for an inverter (with space for a second breaker for a
second inverter - order separately) that meets the National Electric PART NUMBER
requirements for disconnection and overcurrent protection of battery-based
power systems. There are knockouts on the sides for four 15 to 100 amp DC
breakers used for charging sources and DC loads.
Use the DC Bonding Block (DCBB
- order separately below) for connecting the negative cables and for
single-point DC system grounding.
There are pre-drilled places inside for
two metering shunts. Knock-outs on the top are provided for mounting two Xantrex C-Series or OutBack MX-60 PV charge controllers, or one RVPP Solar
Boost PV charge controller. Knockouts on the sides are designed for mounting
two Xantrex SW, SW-Plus, or DR inverter/chargers with their optional conduit
boxes and 2" offset nipples.
Order 175A or 250A DC surface mount
circuit
breakers listed below for adding second inverter breaker. Order 15A to 100A
DC panel
mount
circuit breakers to use in the DC Disconnect side spaces.
Use the DC175 for
the Xantrex SW4048, SW-Plus 2524 & 2548, DR1512, DR1524, and DR2424
inverters.
Use the DC250 for the Xantrex SW4024, SW5548, DR2412, and DR2436
inverters.
ETL listed to UL508.
Dimensions: 21""H x 10.5""W x 5""D.
Weight:
14 lbs
|
Xantrex Model |
Description |
PART NUMBER
|
OUR PRICE |
Purchase |
|
DC250 |
Xantrex 250A DC Disconnect |
030-01414 |
$329 |
 |
|
DC175 |
Xantrex 175A DC Disconnect |
030-01411 |
$329 |
 |
|
DCBB |
DC Bonding Block |
030-01417 |
$50 |
 |
|
|
TOP |
MidNite Solar
Mini-DC Disconnect Power Center
Use this small DC disconnect, which includes the inverter breaker, to
provide over current protection for any single inverter.
It has a DIN rail for additional rail mounted breakers for DC
inputs or loads and it is pre-drilled for a shunt and optional bus bars
listed below.
The white powder coated aluminum chassis measures 10" X 5" X 18"
and weighs 7 pounds.
Three main breakers sizes are available.
|
Model
|
Description
|
PART NUMBER
|
OUR PRICE
|
Purchase |
| MNDC125 |
125A mini-DC disconnect
|
053-00091 |
$205 |
 |
| MNDC175 |
175A mini-DC disconnect
|
053-00092 |
$235 |
 |
| MNDC250 |
250A mini-DC disconnect
|
053-00093 |
$235 |
 |
|
|
TOP |
Baby Box
AC or DC Distribution Center or as a PV Combiner.
The Bay Box encloses up to four MNEPV or MNEAC DIN rail breakers. It
is a general-use enclosure for retrofits, a small inverter disconnect, a PV
disconnect or a small AC or DC distribution center.
It has concentric ¾" and 1" knockouts at each end. Breakers are
not included.
Boxed: 3" x 3" x 7" and weighs 2 pounds.
|
Model
|
Description
|
PART NUMBER
|
OUR PRICE
|
Purchase |
| BAY BOX |
Baby box breaker center
|
053-00089 |
$36 |
 |
|
Accessories
| These UL Recognized components can be use in the
Mini-DC Disconnect and Baby Box above.
Busbars with colored insulators. Each has four 1/0 and
eleven #6 usable wire slots, with two sizes of 10-32 screws.
4.63" long.
Ground busbar, 3.45" long with green screws. Two 1/0
and seven #6 wire slots with mounting screws.
|
|
Model |
Description
|
PART NUMBER
|
OUR PRICE
|
Purchase |
| MNTBR |
Red terminal
busbar |
053-00105 |
$17 |
 |
| MNTBB |
Black terminal
busbar |
053-00106 |
$17 |
 |
| MNTBW |
White terminal
busbar |
053-00107 |
$17 |
 |
| MNGBB |
Ground busbar |
053-00100 |
$14 |
 |
|
|
|
TOP |
DC Circuit Breakers
These single pole circuit breakers are UL listed for use in DC circuits with
voltages up to 125VDC. They are commonly used in DC power centers as overcurrent protection and disconnecting means between PV arrays and charge
controllers, between charge controllers and batteries, between other DC
charging sources (such as wind and hydro generators) and batteries, and as
outputs to DC loads.
They have the high amp interrupting capacity (AIC)
needed between batteries and Square-D QO and QOU circuit breakers and load
centers for 12V and 24V systems.
Breakers are Heinneman, Airpax, or
Carlingswitch brand.
They are available in two different configurations:
PANEL MOUNT
SURFACE MOUNT |
|
|
Panel (Front) Mount Breakers
The panel
mount
version is designed to be mounted from the front, behind a panel with
rectangular knockouts. They have stud terminals on their back side for wire
connection with a ring terminal or a barrel connector.
The 15A to 30A
breakers have a #10 stud terminal, and the 50A to 100A breaker have a 1/4"
stud terminal.
Use panel mount breakers in the side spaces of the Xantrex DC Disconnect
and Power Modules, and in the medium and large breaker spaces in the OutBack
PS2DC and PS4DC.
|
|
Panel Mount DC Circuit Breakers
Stud Terminal |
|
Model Number |
Amps |
PART NUMBER
|
OUR PRICE |
Purchase |
|
CD10-PM |
10
|
053-01010 |
$25 |
 |
|
CD15-PM |
15
|
053-01015 |
$25 |
 |
|
CD20-PM |
20
|
053-01020 |
$25 |
 |
|
CD30-PM |
30
|
053-01025 |
$25 |
 |
|
CD50-PM |
50
|
053-01030 |
$25 |
 |
|
CD60-PX |
60
|
053-01192 |
$35 |
 |
|
CD75-PM |
75
|
053-01040 |
$35 |
 |
|
CD80-PM |
75
|
053-01189 |
$35 |
 |
|
CD100-PM |
100
|
053-01050 |
$39 |
 |
|
GJ1-175-B3 |
175
|
030-04329 |
$119 |
 |
|
GJ1-250-B3 |
250
|
030-04326 |
$119 |
 |
|
Surface Mount DC Circuit Breakers
Lug Terminals |
|
Model Number |
Amps |
PART NUMBER
|
OUR PRICE |
Purchase |
|
CD10-SM |
10 |
053-01011 |
$25 |
 |
|
CD15-SM |
15 |
053-01016 |
$25 |
 |
|
CD20-SM |
20
|
053-01021 |
$25 |
 |
|
CD30-SM |
30
|
053-01026 |
$25 |
 |
|
CD50-SM |
50 |
053-01031 |
$25 |
 |
|
CD60-SM |
60 |
053-01036 |
$35 |
 |
|
CD75-SM |
75 |
053-01041 |
$35 |
 |
|
CD100-SM |
100 |
053-01051 |
$39 |
 |
|
CD110-SM |
110 |
053-01055 |
$60 |
 |
|
GJ1-175-SM |
175 |
053-01056 |
$119 |
 |
|
GJ1-250-SM |
250 |
053-01061 |
$119 |
 |
|
GJ1 Rear Mounting Kit |
053-01066 |
$10 |
 |
|
Surface Mount Breakers
The surface
mount
version is designed to be mounted on a flat surface behind the breaker and
has lug type terminals that accept wire sizes from #14 to #2 AWG on the 15A
to 100A sizes, and wire up to 250MCM on the larger breakers. Surface mount
breakers can be used in the GFI Enclosure, in some older power
centers, and to mount in custom combiner boxes and power centers.
Use these
breakers in the 175A and 250A sizes for mounting in the front spaces of the Xantrex DC Disconnect for use as inverter breakers (GJ1 Mount Kit required).
|
|
|
TOP |
Class T Fuse Blocks with Fuses
Use these single pole fuse blocks to fuse inverters or other large loads.
Holders with set screw lugs accept up to 2/0 wire in the 110A and 200A sizes
and up to 4/0 wire in the 300A and 400A sizes.
On stud mount holders, a 5/16" bolt at each end of the fuse allows
connection of a cable with a ring lug terminal end. To connect an inverter,
order two cables with lugs on both ends: one to go from the battery to the
fuse and one to go from the fuse to the inverter.
Class T fuses exceed the 10,000 amp interrupting capacity (AIC) required
to protect Square-D brand circuit breakers in DC load centers. They are UL
listed for up to 160VDC and NEC approved for inverter use. A fuse comes
installed in the block. Order spare fuses separately.
|
Xantrex Model |
Description |
PART NUMBER
|
OUR PRICE |
Purchase |
|
TFB110C |
110A fuse and holder
w/screw lug |
053-02515 |
$53 |
 |
|
TFB200C |
200A fuse and holder
w/screw lug |
053-02532 |
$53 |
 |
|
TFB300C |
300A fuse and holder
w/screw lug |
053-02550 |
$75 |
 |
|
TFB400C |
400A fuse and holder
w/screw lug |
053-02562 |
$75 |
 |
|
TFB110 |
110A fuse and holder
w/studs |
053-02512 |
$53 |
 |
|
TFB200 |
200A fuse and holder
w/studs |
053-02526 |
$53 |
 |
|
TFB300 |
300A fuse and holder
w/studs |
053-02544 |
$75 |
 |
|
TFB400 |
400A fuse and holder
w/studs |
053-02559 |
$75 |
 |
|
|
TOP |
Class T Fuses - JJN Series
These class T Fuses are rated for 160 VDC and 300 VAC as protection for
circuit breakers, load centers and inverters where high available short
circuit currents are possible. These fuses fit the fuse blocks above and the
Inline holder at right.
|
Model |
Description |
PART NUMBER
|
OUR PRICE |
Purchase |
|
TF110 |
110A replacement fuse |
053-02509 |
$18 |
 |
|
TF200 |
200A replacement fuse |
053-02520 |
$18 |
 |
|
TF300 |
300A replacement fuse |
053-02538 |
$38 |
 |
|
TF400 |
400A replacement fuse |
053-02556 |
$38 |
 |
|
|
TOP |
Inline Class T Fuse Receptacle
This is a great way to retrofit an inverter cable with an NEC approved fuse.
To install the fuse holder and fuse, just cut the positive cable, remove an
inch of insulation from each side of the cut, insert the wire in the
terminal blocks, tighten the set screws and tighten the strain relief at
each end of the holder.
Fits up to 4/0 cable.
The fuse is not included. It holds 110 to 400 amp
fuses. Order fuse below on left.
Dimensions are 11" x 2.5" x 3".
|
Description |
PART NUMBER
|
OUR PRICE |
Purchase |
|
Class T Inline Fuse Holder |
053-02563 |
$38 |
 |
|
|
TOP |
Square-D QO Circuit Breakers

QO circuit breakers snap into QO load centers on the next page . They are UL
listed for DC branch circuits up to 48VDC (not for use in 48V systems). They
can also be used for 120VAC (1-pole) or 120/240VAC (2-pole) circuits.
Circuit breakers in 10A to 30A sizes can handle one or two #14 to #10 wires
or one #8 wire. Circuit breakers 40A to 70A will handle #8 to #2 wire sizes.
QOU circuit breakers are designed for surface or din rail mounting and
are used in the Xantrex T-240 and in SWPlus AC conduit boxes.
|
Description |
QO Breakers |
QOU Breakers |
|
Part # |
PART NUMBER
|
OUR PRICE |
Purchase |
Part # |
PART NUMBER
|
OUR PRICE |
Purchase |
|
10 Amp 1 Pole |
QO110 |
053-02063 |
$12 |
 |
QOU110 |
053-02006 |
$25 |
 |
|
15 Amp 1 Pole |
QO115 |
053-02065 |
$12 |
 |
QOU115 |
053-02009 |
$25 |
 |
|
20 Amp 1 Pole |
QO120 |
053-02071 |
$12 |
 |
QOU120 |
053-02015 |
$25 |
 |
|
30 Amp 1 Pole |
QO130 |
053-02075 |
$12 |
 |
QOU130 |
053-02024 |
$25 |
 |
|
40 Amp 1 Pole |
QO140 |
053-02080 |
$12 |
 |
QOU140 |
053-02030 |
$25 |
 |
|
50 Amp 1 Pole |
QO150 |
053-02083 |
$12 |
 |
QOU150 |
053-02036 |
$25 |
 |
|
60 Amp 1 Pole |
QO160 |
053-02086 |
$13 |
 |
QOU160 |
053-02042 |
$25 |
 |
|
70 Amp 1 Pole |
QO170 |
053-02090 |
$28 |
 |
QOU170 |
053-02048 |
$55 |
 |
|
15 Amp 2 Pole |
QO215 |
053-02067 |
$24 |
 |
QOU215 |
053-02012 |
$50 |
 |
|
20 Amp 2 Pole |
QO220 |
053-02073 |
$24 |
 |
QOU220 |
053-02018 |
$50 |
 |
|
30 Amp 2 Pole |
QO230 |
053-02077 |
$24 |
 |
QOU230 |
053-02027 |
$50 |
 |
|
40 Amp 2 Pole |
QO240 |
053-02081 |
$24 |
 |
QOU240 |
053-02033 |
$50 |
 |
|
50 Amp 2 Pole |
QO250 |
053-02084 |
$24 |
 |
QOU250 |
053-02039 |
$50 |
 |
|
60 Amp 2 Pole |
QO260 |
053-02088 |
$22 |
 |
QOU260 |
053-02045 |
$50 |
 |
|
|
TOP |
AC Breakers,
DIN mount
These breakers come with set-screw compression terminals for 14 to #2AWG
wire.
Use these for AC in OutBack FLEXware and MidNite E-panels.
Breaker amps
|
Poles |
Voltage rating |
Frequency rating |
Width (inches)
|
OutBack |
MidNite Solar |
PART NUMBER
|
OUR PRICE |
Purchase |
| 15 |
1 |
120 |
50/60HZ AC |
0.5 |
OBB-15-120VAC-DIN
|
MNEAC15 |
030-04415 |
$19 |
 |
| 15D |
2 |
120/240 |
50/60HZ AC |
1 |
OBB-15D-240VAC-DIN |
|
030-04416 |
$39 |
 |
20 |
1 |
120 |
50/60HZ AC |
0.5 |
OBB-20-120VAC-DIN
|
MNEAC20 |
030-04418 |
$19 |
 |
| 20D |
2 |
120/240 |
50/60HZ AC |
1 |
OBB-20D-240VAC-DIN
|
|
030-04419 |
$39 |
 |
| 25D |
2 |
120/240 |
50/60HZ AC 9 |
1 |
OBB-25D-240VAC-DIN
|
|
030-04421 |
$39 |
 |
10 |
1 |
277 |
50/60HZ AC |
0.5 |
OBB-10-277VAC-DIN
|
MNEAC10 |
030-04439 |
$19 |
 |
15 |
1 |
277 |
50/60HZ AC |
0.5 |
OBB-15-277VAC-DIN
|
|
030-04440 |
$19 |
 |
30 |
1 |
277 |
50/60HZ AC |
0.5 |
OBB-30-277VAC-DIN
|
MNEAC30 |
030-04437 |
$19 |
 |
| 30D |
2 |
277/480 |
50/60HZ AC |
1 |
OBB-30D-480VAC-DIN
|
|
030-04414 |
$39 |
 |
| 30T |
3 |
277/480 |
50/60HZ AC |
1.5 |
OBB-30T-480VAC-DIN
|
MNEAC30-3P |
030-04435 |
$59 |
 |
| 50 |
1 |
277 |
50/60HZ AC |
0.5 |
OBB-50-277VAC-DIN
|
MNEAC50 |
030-04422 |
$19 |
 |
| 50D |
2 |
277/480 |
50/60HZ AC |
1 |
OBB-50D-480VAC-DIN |
|
030-04423 |
$39 |
 |
| 50T |
3 |
277/480 |
50/60HZ AC |
1.5 |
OBB-50T-480VAC-DIN
|
MNEAC50-3P |
030-04432 |
$59 |
 |
60 |
1 |
277 |
50/60HZ AC |
0.5 |
OBB-60-277VAC-DIN
|
MNEAC60 |
030-04431 |
$29 |
 |
| 60D |
2 |
277/480 |
50/60HZ AC |
1 |
OBB-60D-480VAC-DIN
|
|
053-03036 |
$41 |
 |
|
|
TOP |
DC Breakers, Panel
MountedPanel mount breakers with stud terminals. Ring
terminals on wire are required. Use these breakers for DC protection in
OutBack FLEXware enclosures, and
MidNite E-panels when equipped for the Apollo T-80 controller. Stud size is
1/4" on 80A and smaller, 5/16" on 100A and 125A and 3/8" on 175A and 250A.
Breaker amps
|
Poles |
Voltage rating |
Frequency rating |
Width (inches) |
OutBack |
MidNite Solar |
Generic |
PART NUMBER
|
OUR PRICE |
Purchase |
| 1 |
1 |
150 |
AC/DC |
0.75 |
OBB-1-150VDC120VAC-PNL
|
|
LELK1-1 |
030-04350 |
$25 |
 |
| 5 |
1 |
150 |
AC/DC |
0.75 |
OBB-5-150VDC120VAC-PNL
|
|
LELK1-5 |
030-04349 |
$25 |
 |
| 10 |
1 |
150 |
AC/DC |
0.75 |
OBB-10-150VDC120VAC-PNL
|
|
LELK1-10 |
030-04348 |
$25 |
 |
| 15 |
1 |
150 |
AC/DC |
0.75 |
OBB-15-150VDC120VAC-PNL
|
|
LELK1-15 |
030-04344 |
$25 |
 |
| 20 |
1 |
150 |
AC/DC |
0.75 |
OBB-20-150VDC120VAC-PNL
|
|
LELK1-20 |
030-04347 |
$25 |
 |
| 30 |
1 |
150 |
AC/DC |
0.75 |
OBB-30-150VDC120VAC-PNL
|
|
LELK1-30 |
030-04341 |
$25 |
 |
| 40 |
1 |
150 |
AC/DC |
0.75 |
OBB-40-150VDC120VAC-PNL
|
|
LELK1-40 |
030-04338 |
$25 |
 |
| 50 |
1 |
150 |
AC/DC |
0.75 |
OBB-50-150VDC120VAC-PNL
|
|
LELK1-50 |
030-04337 |
$25 |
 |
| 60 |
1 |
150 |
AC/DC |
0.75 |
OBB-60-150VDC120VAC-PNL
|
|
LELK1-60 |
030-04335 |
$25 |
 |
| 70 |
1 |
150 |
DC |
0.75 |
OBB-70-150VDC-PNL
|
MNEDC70 |
|
030-04334 |
$25 |
 |
| 80 |
1 |
150 |
DC |
0.75 |
OBB-80-150VDC-PNL
|
MNEDC80 |
|
030-04333 |
$25 |
 |
| 100 |
1 |
150 |
DC |
1.0 |
OBB-100-150VDC-PNL |
|
|
030-04332
|
$59 |
 |
| 125 |
1 |
150 |
DC |
1.0 |
OBB-125-150VDC-PNL
|
MNEDC125 |
|
030-04331 |
$59 |
 |
| 175 |
1 |
150 |
DC |
1.5 |
OBB-175-150VDC-PNL
|
MNEDC175 |
|
030-04329 |
$129 |
 |
| 250 |
1 |
150 |
DC |
1.5 |
OBB-250-150VDC-PNL |
MNEDC250 |
|
030-04326 |
$129 |
 |
|
|
TOP |
DIN Rail Mount Fuse Holders and Fuses
Fuse holder and fuses fit both the MidNite
MNPV and OutBack FlexPV combiners.
Use these fuses and fuse holder for 600VDC array combiners. Fuses are KLKD
for 600 VDC.
|
Amps
|
Description |
PART NUMBER
|
OUR PRICE |
Purchase |
|
USM1 Fuse
Holder - 600V 30A Max - DIN mount |
053-03040 |
$20 |
 |
| 1
|
1 amp 600 VDC KLKD fuse
|
053-03155 |
$12.50 |
 |
| 2
|
2 amp 600 VDC KLKD fuse
|
053-03052 |
$12.50 |
 |
| 4
|
4 amp 600 VDC KLKD fuse |
053-03051 |
$12.50 |
 |
| 6
|
6 amp 600 VDC KLKD fuse
|
053-03050 |
$12.50 |
 |
| 8
|
8 amp 600 VDC KLKD fuse
|
053-03048 |
$12.50 |
 |
| 10
|
10 amp 600 VDC KLKD fuse
|
053-03046 |
$12.50 |
 |
| 12
|
12 amp 600 VDC KLKD fuse
|
053-03044
|
$12.50 |
 |
| 15
|
15 amp 600 VDC KLKD fuse
|
053-03043 |
$12.50 |
 |
| 20
|
20 amp 600 VDC KLKD fuse |
053-03042 |
$12.50 |
 |
| 30
|
30 amp 600 VDC KLKD fuse |
053-03041 |
$12.50 |
 |
|
|
TOP |
DIN Rail Mount Combiner Breakers
These breakers
fit both the MidNite MNPV and OutBack PSPV combiners.
Use breakers for arrays with maximum voltage of
150 or less. Use the fuses and fuse holder below for
600VDC array combiners.
|
|
TOP
|
|
|
|